DESIGN AND APPLICATION OF A SIZE SELECTIVE CYCLONE SEPARATOR INLET FOR HIGH VOLUME SAMPLERK.V.V.N. SATYANARAYANA, A. VINOD KUMAR AND R.S. PATILAbstract A PM 10 size selective cyclone sampler inlet for existing high volume sampler is designed, fabricated and calibrated. Various design parameters used for the fabrication and its calculations are discussed. The separation efficiency for particles lower than 10 pirn s 91%. The cost is much less than the respirable particulate sampler available in the market.